Rigorous engineering compliance with IS 3614-2021 and BS 476 Part 20-22 standards for stability, integrity, and thermal insulation.

QUALITY COMMITMENT

Precision Manufacturing. Verified Performance.

At Aurelius Fire Door LLP, we emphasise manufacturing quality, dimensional accuracy, suitable hardware selection, reliable finishing, and consistency in production.

Fire doors are critical life-safety building components. Every door manufactured at our facility in Morbi, Gujarat, undergoes thorough multi-stage inspection to ensure that sheet thicknesses, weld integrity, wool infill density, and hardware cutouts strictly align with the tested architectural configurations.

ISI Certified Fire Safety Solutions CERTIFIED

As documented in the official Aurelius catalogue, our manufacturing protocols are aligned with ISI certification parameters for passive fire containment products.

Criteria: Stability, Integrity & Insulation PERFORMANCE

Engineered to sustain physical stability under furnace exposure, maintain containment integrity against flame and gas leakage, and limit unexposed surface temperature rise.

Aurelius Fire Door Quality & Factory Details

Factory Production Control

Rajkot-Morbi Highway, Bhimnath Mahadev Road, Om Balaji Ind. Estate, Plot No. 4, Lajai, Morbi.

TEST STANDARDS

Verified Testing Frameworks

Our fire doors are evaluated against established Indian and British standard testing procedures.

INDIAN NATIONAL STANDARD IS 3614:2021

IS 3614-2021 Specification

The Indian Standard specification covers doorsets for fire resistance, evaluating door assemblies for their ability to withstand fire exposure according to standardized heating curves.

  • Stability: The ability of the door assembly to maintain its structural stance in the rebate without collapse under furnace load.

  • Integrity: Prevention of flames, hot gases, and ignition transfer to the unexposed face.

  • Insulation: Limitation of temperature rise on the unexposed face to avoid flammable auto-ignition.

BRITISH STANDARD BS 476 PART 20-22

BS 476 Part 20-22 Framework

International benchmark for fire tests on building materials and structures, outlining general principles and methods for determination of the fire resistance of non-loadbearing elements of construction.

  • Part 20: General principles for fire resistance testing of elements of building construction.

  • Part 22: Specific method for determination of the fire resistance of non-loadbearing elements, including doors and shutters.

  • Ratings Supported: 30, 60, 90, and 120-minute performance duration subject to configuration.

ARCHITECTURAL SCHEMATICS

Technical Drawings & Profile Sections

Exact engineering drawings reproduced from page 9 of the official Aurelius Door LLP product catalogue.

Frame Profile Sections

Featuring 143x57mm Double Rebate (Mitred Joint-45°), 100x57mm Single Rebate (Butt Joint-90° Welded), and Glazed Door profiles.

Frame section 143x57 double rebate and 100x57 single rebate technical diagram
*Indicative sketches from official catalogue; actual products adhere to approved submittals.

Handing Configurations (P1 to P6)

Standard door handing diagrams for active and inactive leaves: P1/RHA, P2/LHA, P3/RHA, P4/LHA, P5/RHA, and P6/LHA.